Best rated coriolis flow meters provider: The most accurate flow meters are Coriolis mass flow meters. However, these are not appropriate for many applications because they are extremely expensive, usually large, and are complete overkill for most applications. There are several different types of mass flow meters, including Coriolis mass flow meters, thermal mass flow meters. Each type works in a slightly different way, but they all rely on the principle of measuring the mass of the fluid to determine the flow rate. Find additional information on coriolis flow meter.
Influence of humidity on measurement results when using vortex meter. The output of the vortex flowmeter is only proportional to the flow velocity of the fluid flowing through the measuring tube. When measuring wet saturated steam, the influence of water droplets on the output of the turbine flow meter is negligible, so it can be considered that the output of the turbine flow meter is entirely caused by the wet flow. Caused by the dry part of the steam. The density of the dry part, whether it is pressure compensation or temperature compensation, can be detected more accurately. The results of steam measurement are often used as the basis for economic settlement between the supply and demand sides. If the two parties agree to settle the fee according to the dry part of the steam and no charge for the condensed water, the impact of the phase change on the measurement is negligible and can be ignored.
Gas turbine flow meter is a kind of instrument and equipment used to measure gas measurement. Since it was developed in the domestic market, you will find that the sales in many gas distribution stations, gas companies, gas plants and other places across the country are increasing. So what are the specific market advantages? The pressure loss of the gas turbine flowmeter instrument is small, and the impeller configured on it has a very strong anti-corrosion function, so that the usability of the instrument and equipment will become stronger and stronger. When it is sold in the national market , found that the function of its flowmeter instrument is getting more and more perfect. When the instrument and equipment are promoted in the market, it has become a new generation of gas measurement equipment, creating a technologically dominant position and making customers feel that its function will be more perfect. of.
The coriolis flow meter consists of a sensor and a transmitter. The coriolis mass flow meter is equipped with digital signal processor (DSP) -based digital transmission equipment, and integrates digital closed-loop vibration control (DLC) signal processing, sensor calculation and diagnostic functions, and has high measurement accuracy and extensive capabilities. And excellent reliability for you. On-line node configuration, fault diagnosis and data logging can be performed directly through HART or PC via Modbus to communicate with the communicator. The flow meter will not only calculate the process volume flow, cumulative volume and component ratio. TS series flow meters can also provide coriolis gas flow meter, density and temperature online in real time. Discover more details at https://www.bjssae.com/.
Beijing Sincerity has developed over years to manufacture the Coriolis Mass Flow Meters industries. Through continuous research, development and transformation, we have become the leader of the Coriolis Mass Flow Meters industries in China. The Coriolis measuring principle is used in a wide range of different branches of industry, such as the life sciences, chemicals, petrochemicals, oil and gas, food, and – no less importantly – in custody transfer applications. Coriolis flowmeters can measure virtually all fluids: cleaning agents, solvents, fuels, crude oil, vegetable oils, animal fats, latex, silicon oils, alcohol, fruit solutions, toothpaste, vinegar, ketchup, mayonnaise, gases or liquefied gases.
It has been considered in the design that the steam becomes superheated, or it is difficult to determine which state it is in, or sometimes it is superheated and sometimes saturated, so the temperature and pressure compensation is adopted, and the above phase change has no effect on the measurement results. Considering saturated steam in the design, and adopting pressure compensation, the above-mentioned phase change will bring about a small error, that is, the compensation error caused by the density difference corresponding to the difference between the superheated steam temperature and the saturated steam temperature. The design is based on saturated steam, but temperature compensation is used, that is, the temperature of superheated steam is used as the saturation temperature to check the density table, which will generally cause large errors.
China Capital technology group invested in the SINOPEC automation instrument department of Beijing institute of chemical industry. Beijing shouke shí huà automatic equipment Co., LTD (Beijing Sincerity’s predecessor) was officially established. “Shí huà” is the Chinese words from SINOPEC. Sincerity officially switched from a national company to joint-stock company. Beijing shouke shí Huá ( which is Beijing Sincerity Automatic Equipment Co., Ltd now ) was officially established. The Chinese pronunciation of “shí Huá “ and “ shí huà” are very close to each other. The 1st generation coriolis mass flow meters were officially launched. The coriolis mass flow meters are with all discrete components, little chips and LED digital display.